P+F
Prompt, Courteous Service for All Your Automation and Safety Needs.
Category
-
Original P+F Photoelectronic Distance Sensor OMR50M-R1000-SSI-V1V1B China supplier
Original P+F distacne sesnor The OMR50M-R1000-SSI-V1V1B distance sensor for positioning tasks accurate to the millimeter, PRT. The detectiing distacne can be up to 50 m. The interface is SSI/RS-422 with M12 plug. The R1000 series is based on pulse ranging technology (PRT) by Pepperl+Fuchs P+F. For small and large ranges, these distance sensors are very precise which makes them ideally suitable for positioning tasks. The red laser diode is clearly visible, allowing direct alignment of the device for reliable operation.View More
-
Original P+F Female cordset sensor-actuator cable V1-G-2M-PVC
Original P+F Female cordset sensor-actuator cable V1-G-2M-PVCView More
-
P+F Passive splitter AS-Interface splitter box VAZ-T1-FK-G10-0,3M-PUR-V1-G
View More
-
Original P+F Safety Barrier Isolated Barrier KFD2-SR2-Ex2.W
This isolated barrier is used for intrinsic safety applications.
The device transfers digital signals from NAMUR sensors or dry contacts from the hazardous area to the non-hazardous area.
The proximity sensor or the mechanical contact controls the control side load for a relay contact output. The device output changes the state when the input signal changes the state.
Via switches the mode of operation can be reversed and the line fault detection can be switched off.
During a fault condition, the relay reverts to its de-energized state and the LEDs indicate the fault according to NAMUR NE 44.
If the device is operated via Power Rail, additionally a collective error message is available.
View More
-
P+F Safety Barrier Isolated Barrier KFD2-STC5-Ex2
This isolated barrier is used for intrinsic safety applications.
The device supplies 2-wire and 3-wire SMART transmitters, and can also be used with 2-wire SMART current sources.
It transfers the analog input signal to the safe area as an isolated current value.
Digital signals may be superimposed on the input signal in the hazardous or non-hazardous area and are transferred bi-directionally.
The device provides a sink mode or a source mode output on the safe area terminals.
The device has an internal resistor. Use this resistor if the HART communication resistance in the control circuit is too low.
Test sockets for the connection of HART communicators are integrated into the terminals of the device.
It supports HART, Foxboro, BRAIN.
View More
-
Original P+F Safety Barrier Isolated Barrier KFD2-UT2-Ex2
This isolated barrier is used for intrinsic safety applications. The device converts the signal of a resistance thermometer, thermocouple, or potentiometer to a proportional output current. The device can also be configured as a signal splitter. The removable terminal block K-CJC-** is available as an accessory for internal cold junction compensation of thermocouples. A fault is signalized by LEDs acc. to NAMUR NE44 and a separate collective error message output. The device is easily configured by the use of the PACTware configuration software.